FB LI YT EB


Manufacturers of Marine and Industrial Air Conditioners & Chillers





Home HomeMobile Version AvailableMobile Version




 
  Ocean Breeze >‎ Chillers >‎ Seawater-cooled Chillers


BARCO CHILLERS
Ocean Breeze MFG.

Seawater-cooled or Brine-cooled Chillers

For Chilled Water A/C Systems and Tempered Water Systems

Barco Chillers™ Mfd. by Ocean Breeze

Single Compressor Chiller Specifications follow link  |  Dual Compressor Chiller Specifications follow link  |  Semi-hermetic Unit Specifications follow link

Air-cooled Chillers follow link  |  Fan Coil Units for Chillers follow link  |   Seawater-cooled Chiller Installation follow link

60,000 BTU (5-Ton) Water-cooled Chiller (Model CW60)

60,000 BTU (5-Ton) Water-cooled Chiller (Model CW60)
Popularly used in chilled water air conditioning for boating and marine applications.




Seawater or Brine-cooled Chiller, 24,000 to 420,000 BTUs

Seawater or Brine-cooled Chiller, 24,000 to 420,000 BTUs



Seawater or Brine Chiller

Seawater or Brine Chiller



Available in white epoxy painted for extra protection.

Available in white epoxy paint for extra protection.











Water-cooled chillers can be designed to be stacked or in series.
Click on the YouTube Link below for details





Custom-made 15 Ton Triple Chiller Assembly (back)

45 Ton Triple Chiller System
(Three 15 Ton Chiller Assembly)

From 6 ton up to 150 ton available. Ready for installation. Vertical configuration is available.
Completely assembled in the factory. Can be taken apart completely, and then reassembled and installed onboard a yacht.



Custom-made 15 Ton Triple Chiller Assembly (front)

45 Ton Triple Chiller System
(Three 15 Ton Chiller Assembly)

The above modular Ocean Breeze chiller is designed for retrofit or new yacht installation, from small yachts to mega yachts. Typical lead time is 6 weeks from the time our draftsman measures the existing equipment aboard the yacht to the completion of the installation. Drawings in SolidWorks format from our engineering department are then submitted for approval along with complete electrical system design. The completed modular chillers are then assembled and tested in the factory, disassembled prior to delivery, and then reassembled aboard the yacht. Average installation by a two-man team takes about 10-14 days.






Seawater-cooled Chiller with Cleanable Titanium Evaporator for Seafood or Aquarium Applications

4 Ton Seawater-cooled Chiller
with Cleanable Titanium Evaporator
for Seafood or Aquarium Applications


Semi-hermetic Chiller for Refrigeration, Freezers, or Air Conditioning

Semi-hermetic Chiller for
Refrigeration, Freezers, or Air Conditioning
for Naval and Ship Applications
Up to 500 Ton

Chillers that are 40 ton and up use the energy-efficient Bitzer CSW
series semi-hermetic compact screw compressor technology.



Complete Certified Testing of Mechanical, Electrical, and Full-load Operation.





12,000 to 42,000 BTU Chiller
48,000 to 96,000 BTU Chiller
1.5 to 3 Ton Seawater-cooled Chiller with Titanium Evaporator
12,000 to 42,000 BTU Chiller
48,000 to 96,000 BTU Chiller
1.5 to 3 Ton Seawater-cooled Chiller
with Titanium Evaporator


4 to 7 Ton Chiller Up to 72,000 BTU
8 to 15 Ton Chiller Up to 180,000 BTU
12 to 15 Ton Chiller with Manifold
4 to 7 Ton Chiller
Up to 72,000 BTU
8 to 15 Ton Chiller
Up to 180,000 BTU
12 to 15 Ton Chiller with Manifold


5 Ton Dual Compressor Chiller
30 Ton Dual Compressor Chiller
10 Ton to 75 Ton Semi-hermetic Chiller
5 Ton Dual Compressor Chiller
30 Ton Dual Compressor Chiller
10 Ton to 75 Ton
Semi-hermetic Chiller


Multiple Stage Chiller up to 500 Ton
Chiller for Motor Coach
5 to 30 Ton Package Water Cooled Chiller
Multiple Stage Chiller up to 500 Ton
Chiller for Motor Coach
5 to 30 Ton Package Water Cooled Chiller


Custom Cupro-nickel Manifolds

Custom Cupro-nickel Manifolds are Available




Water-cooled Chiller (Model CW60; 5-Ton/60,000 BTU)

Barco Chillers CW60 5-Ton (60,000 BTU) Seawater-cooled Chiller


Call 866-227-7773 for a Quote or to Place an Order
  Model
Number
Power Type Capacity Voltage Amps 1Ph/3Ph Amps
3Ph
460 Volt
Height
(A)
Width
(B)
Length
(C)
Weight Exit
Water
Temp.
1/2 Ton Seawater-cooled Chiller
CW106SR
0.5 hp
(372.85 W)
Rotary 6,000 BTU
(1.76 kWh)
(1,513.0 kcal)
120 6.0  
13"
(330.2 mm)
13"
(330.2 mm)
17.5"
(444.5 mm)
88 lbs.
(39.92 kg)
44°F
(6.67 °C)
1 Ton Seawater-cooled Chiller
CW112SR
1.0 hp
(745.7 W)
Rotary 12,000 BTU
(3.52 kWh)
(3,026.0 kcal)
120 11.0  
13"
(330.2 mm)
13"
(330.2 mm)
17.5"
(444.5 mm)
95 lbs.
(43.09 kg)
44°F
(6.67 °C)
1.4 Ton Seawater-cooled Chiller
CW117SR
1.2 hp
(894.84 W)
Rotary 17,000 BTU
(4.98 kWh)
(4,287.0 kcal)
120 13.8  
16"
(406.4 mm)
14"
(355.6 mm)
16.25"
(412.75 mm)
101 lbs.
(45.81 kg)
44°F
(6.67 °C)
2 Ton Seawater-cooled Chiller
CW224SS
2.0 hp
(1,491.4 W)
Scroll 24,000 BTU
(7.03 kWh)
(6,051.9 kcal)
240 11.4/7.85 3.9
17"
(431.8 mm)
17"
(431.8 mm)
18"
(457.2 mm)
127 lbs.
(57.61 kg)
44°F
(6.67 °C)
3 Ton Seawater-cooled Chiller
CW236SS
3.0 hp
(2,237.1 W)
Scroll 36,000 BTU
(10.55 kWh)
(9,077.9 kcal)
240 17.9/11.4 5.7
19"
(482.6 mm)
19"
(482.6 mm)
20"
(508 mm)
144 lbs.
(65.32 kg)
44°F
(6.67 °C)
4 Ton Seawater-cooled Chiller
CW48
4.0 hp
(2,982.8 W)
Scroll 48,000 BTU
(14.07 kWh)
(12,104.0 kcal)
240 20.4/13.9 7.1
24.25"
(616 mm)
14"
(355.6 mm)
24"
(609.6 mm)
209 lbs.
(94.80 kg)
44°F
(6.67 °C)
5 Ton Seawater-cooled Chiller
CW60
5.0 hp
(3,728.5 W)
Scroll 60,000 BTU
(17.58 kWh)
(15,130.0 kcal)
240 22.1/16.4 7.8
24.25"
(616 mm)
14"
(355.6 mm)
24"
(609.6 mm)
248 lbs.
(112.49 kg)
44°F
(6.67 °C)
6 Ton Seawater-cooled Chiller
CW72
6.0 hp
(4,474.2 W)
Scroll 72,000 BTU
(21.10 kWh)
(18,155.8 kcal)
240 NA /19.3 9.1
24.25"
(616 mm)
14"
(355.6 mm)
24"
(609.6 mm)
256 lbs.
(116.12 kg)
44°F
(6.67 °C)
8 Ton Seawater-cooled Chiller
CW96
7.0 hp
(5,219.9 W)
Scroll 96,000 BTU
(28.13 kWh)
(24,207.8 kcal)
240 NA /20.7 10.9
28"
(711.2 mm)
19"
(482.6 mm)
28"
(711.2 mm)
284 lbs.
(128.82 kg)
44°F
(6.67 °C)
10 Ton Seawater-cooled Chiller
CW120
10.0 hp
(7,457 W)
Scroll 120,000 BTU
(35.17 kWh)
(30,259.7 kcal)
240 NA /28.6 14.2
28"
(711.2 mm)
19"
(482.6 mm)
28"
(711.2 mm)
302 lbs.
(136.99 kg)
44°F
(6.67 °C)
12 Ton Seawater-cooled Chiller
CW144
11.6 hp
(8,625 W)
Scroll 144,000 BTU
(42.2 kWh)
(36,311.67 kcal)
240 NA /37 17.4
24.5"
(622.3 mm)
20.125"
(511.2 mm)
32.3125"
(820.7 mm)
332 lbs.
(150.59 kg)
44°F
(6.67 °C)
13.33 Ton Seawater-cooled Chiller
CW160
14.6 hp
(10,900 W)
Scroll 160,000 BTU
(46.89 kWh)
(40,346.3 kcal)
240 NA /30.2 14.6
28"
(711.2 mm)
19"
(482.6 mm)
28"
(711.2 mm)
357 lbs.
(161.93 kg)
44°F
(6.67 °C)
15 Ton Seawater-cooled Chiller
CW180
16.0 hp
(11,900 W)
Scroll 180,000 BTU
(52.75 kWh)
(45,389.6 kcal)
240 NA /32.1 16.4
28"
(711.2 mm)
22"
(558.8 mm)
28"
(711.2 mm)
379 lbs.
(171.91 kg)
44°F
(6.67 °C)
16 Ton Seawater-cooled Chiller
CW192
17.0 hp
(12,675 W)
Scroll 192,000 BTU
(56.27 kWh)
(48,415.6 kcal)
240 NA /32.4 16.7
28"
(711.2 mm)
22"
(558.8 mm)
28"
(711.2 mm)
398 lbs.
(180.53 kg)
44°F
(6.67 °C)
20 Ton Seawater-cooled Chiller
CW240
20.0 hp
(14,914 W)
Scroll 240,000 BTU
(70.34 kWh)
(60,519.5 kcal)
240 NA /57.2 28.4
29.875"
(758.8 mm)
26.125"
(663.6 mm)
44.125"
(1,120.8 mm)
* 44°F
(6.67 °C)
25 Ton Seawater-cooled Chiller
CW300
25.0 hp
(18,642.5 W)
Scroll 300,000 BTU
(87.92 kWh)
(75,649.3 kcal)
240 NA /73.6 36.8
29.875"
(758.8 mm)
26.125"
(663.6 mm)
44.125"
(1,120.8 mm)
* 44°F
(6.67 °C)
30 Ton Seawater-cooled Chiller
CW360
30.0 hp
(22,371 W)
Scroll 360,000 BTU
(105.51 kWh)
(90,779.2 kcal)
240 NA /94.2 47.1
29.875"
(758.8 mm)
26.125"
(663.6 mm)
44.125"
(1,120.8 mm)
* 44°F
(6.67 °C)
 

Note: Dimensions or specifications are subject to change without notice, so please contact our Engineering Department if you need specific dimensions or specifications.
*Please contact our Engineering Department for specifications.

Back to Top

Over


Front


Side






Dimensions for our Most Popular Chillers

36,000 BTU, 48,000 BTU, 60,000 BTU, 72,000 BTU, 96,000 BTU, 120,000 BTU & 180,000 BTU

The overall height of these units is greater when including piping and the electrical box.



Dimensions for a 3 Ton Chiller (CW36)

Dimensions for a 3 Ton Chiller (CW36)






Dimensions for a 4 Ton Chiller (CW48)

Dimensions for a 4 Ton Chiller (CW48)






Dimensions for a 5 Ton Chiller (CW60)

Dimensions for a 5 Ton Chiller (CW60)






Dimensions for a 6 Ton Chiller (CW72)

Dimensions for a 6 Ton Chiller (CW72)






Dimensions for an 8 Ton Chiller (CW96)

Dimensions for an 8 Ton Chiller (CW96)






Dimensions for a 10 Ton Chiller (CW120)

Dimensions for a 10 Ton Chiller (CW120)






Dimensions for a 15 Ton Chiller (CW180)

Dimensions for a 15 Ton Chiller (CW180)






36,000 BTU Chiller with Dual Compressors

36,000 BTU Chiller with Dual Compressors



Dual Compressors

Model
Number
Power Type Capacity Voltage Amps 1Ph/3Ph Amps
3Ph
460 Volt
Height
(A)
Width
(B)
Length
(C)
Weight Exit
Water
Temp.
4 Ton Dual Compressor Seawater-cooled Chiller
CW48DS
2/2.0 hp
(2/1,491.4 W)
Dual Scroll 48,000 BTU
(14.07 kWh)
(12,103.9 kcal)
240 11.0/2,
7.37/2
3.69/2
17"
(431.8 mm)
22"
(558.8 mm)
34"
(863.6 mm)
192 lbs.
(87.09 kg)
44°F
(6.67 °C)
5 Ton Dual Compressor Seawater-cooled Chiller
CW60DS
2/2.5 hp
(2/1,864.25 W)
Dual Scroll 60,000 BTU
(17.58 kWh)
(15,129.9 kcal)
240 13.5/2,
9.05/2
460
17"
(431.8 mm)
22"
(558.8 mm)
36"
(914.4 mm)
231 lbs.
(104.78 kg)
44°F
(6.67 °C)
8 Ton Dual Compressor Seawater-cooled Chiller
CW96DS
2/3.5 hp
(2/2,609.95 W)
Dual Scroll 96,000 BTU
(28.13 kWh)
(24,207.8 kcal)
240 17.5/2,
11.73/2
5.86/2
17"
(431.8 mm)
24"
(609.6 mm)
42"
(1066.8 mm)
296 lbs.
(134.26 kg)
44°F
(6.67 °C)
10 Ton Dual Compressor Seawater-cooled Chiller
CW120DS
2/5.0 hp
(2/3,728.5 W)
Dual Scroll 120,000 BTU
(35.17 kWh)
(30,259.7 kcal)
240 24.8/2,
16.6/2
8.31/2
18"
(457.2 mm)
26"
(660.4 mm)
44"
(1117.6 mm)
361 lbs.
(163.75 kg)
44°F
(6.67 °C)
12.33 Ton Dual Compressor Seawater-cooled Chiller
CW148DS
2/6.0 hp
(2/4,474.2 W)
Dual Scroll 148,000 BTU
(43.37 kWh)
(37,320.3 kcal)
240 26.0/2,
17.42/2
8.71/2
18"
(457.2 mm)
26"
(660.4 mm)
44"
(1117.6 mm)
405 lbs.
(183.71 kg)
44°F
(6.67 °C)
20 Ton Dual Compressor Seawater-cooled Chiller
CW240DS
2/10.0 hp
(2/7,457 W)
Dual Scroll 240,000 BTU
(70.34 kWh)
(60,519.5 kcal)
240 NA /
28.6/2
14.2/2
36"
(914.4 mm)
28.25"
(717.6 mm)
45.25"
(1,149.4 mm)
* 44°F
(6.67 °C)
25 Ton Dual Compressor Seawater-cooled Chiller
CW300DS
2/11.6 hp
(2/8,625 W)
Dual Scroll 300,000 BTU
(87.92 kWh)
(75,649.3 kcal)
240 NA/
37/2
17.4/2
36"
(914.4 mm)
28.25"
(717.6 mm)
45.25"
(1,149.4 mm)
* 44°F
(6.67 °C)
26.67 Ton Dual Compressor Seawater-cooled Chiller
CW320DS
2/14.6 hp
(2/10,900 W)
Dual Scroll 320,000 BTU
(93.78 kWh)
(80,692.6 kcal)
240 NA/
30.2/2
14.6/2
36"
(914.4 mm)
28.25"
(717.6 mm)
45.25"
(1,149.4 mm)
* 44°F
(6.67 °C)
30 Ton Dual Compressor Seawater-cooled Chiller
CW360DS
2/16.0 hp
(2/11,900 W)
Dual Scroll 360,000 BTU
(105.51 kWh)
(90,779.2 kcal)
240 NA/
32.1/2
16.4/2
36"
(914.4 mm)
28.25"
(717.6 mm)
45.25"
(1,149.4 mm)
* 44°F
(6.67 °C)
33.33 Ton Dual Compressor Seawater-cooled Chiller
CW400DS
2/17.0 hp
(2/12,675 W)
Dual Scroll 400,000 BTU
(117.23 kWh)
(100,865.8 kcal)
240 NA/
32.4/2
16.7/2
36"
(914.4 mm)
28.25"
(717.6 mm)
45.25"
(1,149.4 mm)
* 44°F
(6.67 °C)
40 Ton Dual Compressor Seawater-cooled Chiller
CW480DS
2/20.0 hp
(2/14,914 W)
Dual Scroll 480,000 BTU
(140.67 kWh)
(121,038.9 kcal)
240 NA /
57.2/2
28.4/2
41.875"
(1,063.62 mm)
28.25"
(717.6 mm)
45.25"
(1,149.4 mm)
* 44°F
(6.67 °C)
50 Ton Dual Compressor Seawater-cooled Chiller
CW600DS
2/25.0 hp
(2/18,642.5 W)
Dual Scroll 600,000 BTU
(175.84 kWh)
(151,298.6 kcal)
240 NA /
73.6/2
36.8/2 * * * * 44°F
(6.67 °C)
60 Ton Dual Compressor Seawater-cooled Chiller
CW720DS
2/30.0 hp
(2/22,371 W)
Dual Scroll 720,000 BTU
(211.01 kWh)
(181,558.4 kcal)
240 NA /
94.2/2
47.1/2 * * * * 44°F
(6.67 °C)

Note: Dimensions or specifications are subject to change without notice, so please contact our Engineering Department if you need specific dimensions or specifications.
*Please contact our Engineering Department for specifications.

Units also available with three and four compressors.

Back to Top

Over


Front


Side


Specifications subject to change without notice.
Please contact Engineering Department for custom orders.

If you do not see a specific product,
please do not hesitate to ask us, and call 866-227-7773.





Semi-hermetic and Screw Chiller Systems
for Industrial and Large Marine Applications



  • All Built to Marine Specification

  • 4 Single Refrigeration Circuit Models - 10 thru 35 Nominal Tons

  • Eight Dual Refrigerant Circuit Models - 20 thru 72 Nominal Tons

  • High Efficiency Accessible Hermetic Motor Compressors

  • Completely Factory Wired and Piped

  • Allen-Bradley PLC Control
  •  
  • Cupro-Nickel Coil

  • Thru-Tube Cleanable Type Marine Condenser

  • Replaceable Cartridge Refrigerant Filter Drier

  • Factory Mounted Operating Controls and Starting Components

  • Charged with Refrigerant and Run-Tested Prior to Shipment

  • Unit can be Built for Custom Specifications


  • Dual Screw Compressors Chiller System

     
    Model
    Number
    Power Type Capacity Voltage Amperage Height Width Length Weight
    120,000 BTU Semi-hermetic Seawater-cooled Chiller System
    CW120SL
    10 hp
    (7,457 W)
    Semi-
    hermetic
    120,000 BTU
    (35.17 kWh)
    (30,259.7 kcal)
    240 / 3 35.0
    36"
    (914.4 mm)
    24"
    (609.6 mm)
    48"
    (1,219.2 mm)
    825 lbs.
    (374.2 kg)
    180,000 BTU Semi-hermetic Seawater-cooled Chiller System
    CW150SL
    15 hp
    (11,185.5 W)
    Semi-
    hermetic
    180,000 BTU
    (52.75 kWh)
    (45 389.6 kcal)
    240 / 3 49.2
    38"
    (965.2 mm)
    28"
    (711.2 mm)
    54"
    (1,371.6 mm)
    955 lbs.
    (433.2 kg)
    240,000 BTU Semi-hermetic Seawater-cooled Chiller System
    CW200SL
    20 hp
    (14,914 W)
    Semi-
    hermetic
    240,000 BTU
    (70.34 kWh)
    (60,519.5 kcal)
    240 / 3 59.0
    42"
    (1,066.8 mm)
    38"
    (965.2 mm)
    69"
    (1,752.6 mm)
    1,272 lbs.
    (577 kg)
    300,000 BTU Semi-hermetic Seawater-cooled Chiller System
    CW250SL
    25 hp
    (18,642.5 W)
    Semi-
    hermetic
    300,000 BTU
    (87.92 kWh)
    (75,649.3 kcal)
    240 / 3 66.5
    49"
    (1,244.6 mm)
    48"
    (1,219.2 mm)
    78"
    (1,981.2 mm)
    1,800 lbs.
    (816.5 kg)
    360,000 BTU Semi-hermetic Seawater-cooled Chiller System
    CW300SL
    30 hp
    (22,371 W)
    Semi-
    hermetic
    360,000 BTU
    (105.51 kWh)
    (90,779.2 kcal)
    240 / 3 72.4
    50"
    (1,270 mm)
    48"
    (1,219.2 mm)
    86"
    (2,184.4 mm)
    2,000 lbs.
    (907.2 kg)
    420,000 BTU Semi-hermetic Seawater-cooled Chiller System
    CW350SL
    35 hp
    (26,099.5 W)
    Semi-
    hermetic
    420,000 BTU
    (123.09 kWh)
    (105,909.0 kcal)
    240 / 3 79.5
    50"
    (1,270 mm)
    48"
    (1,219.2 mm)
    86"
    (2,184.4 mm)
    2,100 lbs.
    (952.5 kg)
    480,000 BTU Semi-hermetic Seawater-cooled Chiller System
    CW400DL
    2 / 20 hp
    (2 / 14,914 W)
    Semi-
    hermetic
    480,000 BTU
    (140.67 kWh)
    (121,038.9 kcal)
    240 / 3 59 / 2
    50"
    (1,270 mm)
    48"
    (1,219.2 mm)
    86"
    (2,184.4 mm)
    2,900 lbs.
    (1,315.4 kg)
    600,000 BTU Semi-hermetic Seawater-cooled Chiller System
    CW500DL
    2 / 25 hp
    (2 / 18,642.5 W)
    Semi-
    hermetic
    600,000 BTU
    (175.84 kWh)
    (151,298.6 kcal)
    240 / 3 64 / 2
    60"
    (1,524 mm)
    52"
    (1,320.8 mm)
    96"
    (2,438.4 mm)
    3,200 lbs.
    (1,451.5 kg)
    720,000 BTU Semi-hermetic Seawater-cooled Chiller System
    CW600DL
    2 / 30 hp
    (2 / 22,371 W)
    Semi-
    hermetic
    720,000 BTU
    (211.01 kWh)
    (181,558.4 kcal)
    240 / 3 71 / 2
    60"
    (1,524 mm)
    52"
    (1,320.8 mm)
    96"
    (2,438.4 mm)
    3,740 lbs.
    (1,696.4 kg)
    840,000 BTU Semi-hermetic Seawater-cooled Chiller System
    CW700DL
    2 / 35 hp
    (2 / 26,099.5 W)
    Semi-
    hermetic
    840,000 BTU
    (246.18 kWh)
    (211,818.1 kcal)
    240 / 3 78 / 2
    60"
    (1,524 mm)
    52"
    (1,320.8 mm)
    96"
    (2,438.4 mm)
    4,190 lbs.
    (1,900.6 kg)


    NOMINAL CAPACITY-TON BASED ON 95° F WATER TEMP.
    ALL UNITS CAN BE ORDERED IN EITHER 208, 220, 240, 380, 440, 480, 560, VOLT 50 OR 60 HZ





    Piping Installation for Chiller System

    Piping Installation for Chiller Air Conditioning System
© Quorum Marine & Electronics, Inc. d/b/a Ocean Breeze™

    Quorum Marine & Electronics, Inc. d/b/a Ocean Breeze™




    Piping Installation for Dual Chillers System

    Piping Installation for Dual Chillers Air Conditioning System
© Quorum Marine & Electronics, Inc. d/b/a Ocean Breeze™

    Quorum Marine & Electronics, Inc. d/b/a Ocean Breeze™


    Do not use CPVC (chlorinated polyvinyl chloride) piping with a chiller system which uses polyolester (POE) oil. Refrigerant leaks in the evaporator/heat exchanger may release polyolester (POE) oil and refrigerant into the chilled water piping. Polyolester (POE) oil and refrigerants break down into acidic compounds (including the sludge-like heptanoic and isononanoic acids) when exposed to water and are therefore incompatible with CPVC (chlorinated polyvinyl chloride) pipes. Exposure to these acidic contaminates may result in pipe softening, degradation, cracking, and failure, especially in areas where the piping is under stress. Polyvinyl ether (PVE) oil is compatible and will not degrade CPVC (chlorinated polyvinyl chloride) piping. It is recommended to drain and flush out any and all chilled water piping when upgrading from a polyolester (POE) oil or mineral oil system to a system which uses polyvinyl ether (PVE) oil.



    Installation Notes

  • Min Seawater Condenser Flow: 2.4 GPM per 12,000 BTU (1 Ton)*

  • Max Seawater Condenser Flow: 3 GPM per 12,000 BTU (1 Ton)*

  • Piping for pump intake and discharge must be at least 4 inches of bronze or cupro-nickel pipes.

  • Max Circulation Water Flow: 3 GPM per 12,000 BTU (1 Ton)

  • Fan Coil can be controlled by motorized valve.

  • 2-way or 3-way or fan cycling

  • All thermostatically controlled.

  • All chillers must be bonded and grounded.

  • Pencil zinc must be installed on condenser manifold discharge.

  • Minimum 30% glycol or 30% antifreeze for chilled water circulation. Do not use automotive antifreeze. Marine antifreeze only.

  • Chilled water piping must not be made from CPVC if the system uses POE oil.

  • Chilled water piping insulation: ½" insulation minimum,
    ¾" insulation recommended.

  • Gate valves are recommended for flow adjustment. If ball valves are used, the handle should be removed after the flow adjustments have been made.

  • Valves used for the seawater piping must be bronze. Valves for the chilled water piping may be either bronze or brass.

  • Make-up water system is optional.

  • Seawater in and out connections can be changed to either side of the condenser coil depending on the application.


  • *Pump selection is very important. Insufficient water flow can cause the condenser coil to reach higher temperatures, accelerate corrosion of the condenser coil, decrease compressor efficiency, and decrease the overall lifespan of the compressor.

    Adequate Water Flow vs. Inadequate Water Flow

    Inadequate water flow will fail to flood the coil and does not have enough pressure to push out air. It will also be unable to cool the condenser and fail to carry away heat from the unit. Failing to flood the condenser will leave air pockets with a turbulent water surface which aerates the water with air bubbles. If the pressure is too low and below the vapor pressure of water, cavitation inception will occur and bubbles will form from dissolved air and water vapor. Air bubbles are caused by cavitation and can cause mechanical erosion from shockwaves from the imploding bubbles. The shockwaves can erode the protective cuprous oxide layer on the cupro-nickel. Without the protective cuprous oxide layer, harmful chemicals such as hydrogen sulfide gas, dissolved in water contaminated by sewage and bacteria, will leave the copper vulnerable to corrosion. Insufficient water flow can cause the condenser coil to reach higher temperatures which can accelerate corrosion reactions.





    Typical Seawater Plumbing Installation for Dual 15 ton Chillers

    Typical Seawater Plumbing Installation for Dual 15 ton Chillers

    1 ½ HP, 109 GPM Seawater Pump

    Piping for pump intake and discharge must be at least 4 inches of bronze or cupro-nickel pipes.
    Heat, high-pressure, and harmonic vibrations can cause PVC to crack and fail.

    2.4 GPM × 15 tons = 36 (Min.) to 45 (Max.) GPM Flow Rate per Chiller
    72 (Min.) to 90 (Max.) GPM Total Flow Rate for Both Chillers

    *GPM testing can be done with an electronic or mechanical guage, or manually with a 5 gallon bucket and a stopwatch.



    Typical Seawater Plumbing Installation for Dual 15 ton Chillers
    with Additional Standby Pump

    Typical Seawater Plumbing Installation for Dual 15 ton Chillers with Additional Standby Pump

    *Seawater-in is on the side of the refrigeration liquid line (never the discharge side) and is labeled as "Water In."
    It is critical to follow the labels. Condenser coils can be ordered and manufactured so that the seawater-in can be on either the left or right side.



    It is recommended to Download the OBAC Commissioning Form and send back to Ocean Breeze for Warranty Record. follow link  |  

    Back to Top





    BARCO CHILLERS
Ocean Breeze MFG.
    Barco Chillers™ Mfd. by Ocean Breeze


    Manufactured with Pride in the USA


    Fan Coil Units for Chillers follow link  |  Stackable Seawater Chillers follow link  |  Water-cooled Condenser Units follow link  |  Air-cooled Chillers follow link

    Custom-made Condenser Coils follow link  |  Air-cooled Chiller Systems for Motor Coaches, Buses, and RVs follow link




    Ocean Breeze
    Manufactured by Quorum Marine & Electronics, Inc.


    Tel (772) 220-0038  |  Toll Free (866) 227-7773  |  Fax (772) 220-0260

    Email us at: obr@oceanbreezeac.com
    Monday - Friday, 9:00 AM - 5:00 PM Eastern Time

    Ocean Breeze™/Barco Chillers™/Whisperaire™ are the property of Quorum Marine & Electronics, Inc.